Radiological
Decontamination

High
pressure water jetting equipment has long been utilized in the nuclear
power industry as a means of surface decontamination. Past results
of waterblast decon have often been viewed as mediocre. The primary
downfall of traditional hydrolase efforts has been the generation
of excessive amounts of effluent water and poorly directed manual
cleaning tools with little or no means of accurate repeatability.

Hennigan Engineering has addressed these concerns in an effort
to increase Dose Reduction Factors without overtaxing Radwaste
systems. We have enhanced the efficiency of manually operated
surface decontamination operations and developed partial remotely-operated
decontamination systems for work in High Rad areas.
The unique challenges which we have encountered have led to innovative
solutions. Beyond our standard surface decon techniques, we have
developed and implemented specialized ICI Guide Tube flushing equipment,
remotely operated Steam Generator Channelhead Decon systems and
designed Cavity Upender Fixture Decon tools.
Our specialized equipment can also be used for tube decon, pipe
decon, RHR tube and head cleaning, coating removal and surface
preparation on concrete and steel.
Custom
designed N2 gas regulated pressure control systems are used on all
of our high pressure water jetting pumps. These regulators are part
of a positive shut off delivery system which by-pass clean non-working
water outside of containment. The utilization of this system can
cut in half the volume of effluent water destined for liquid Radwaste
handling systems. Portable effluent filtration equipment can be
integrated with decontaminating Ultra High Rad equipment to mitigate
the burden of effluent control.
Allow Hennigan Engineering Co., Inc. to put our innovative solutions
to work for you.
|